Article 85 of the Building Standards Act Enforcement Order requires live loads on each part of a building to be calculated according to actual conditions in principle, but allows using tabulated values multiplied by floor area for listed room types. Rooftop plazas and balconies follow the same category-(1) values as residential rooms (1,800 N/sqm for floor structural calculation, 1,300 N/sqm for girders/columns/foundations, 600 N/sqm for seismic force), but for buildings used as schools or department stores, the higher category-(4) values apply (2,900/2,400/1,300 N/sqm).
Extracted facts
3 factsOnly numbers and their conditions are stored, as structured data — never the source's own sentences. Metric and condition names stay in English, as coded.
- 1,800 n_per_sqm
floor structural calc live load(rooftop plaza balcony)
Design- region
- Japan
- method
- 建築基準法施行令第85条 表(1)欄
- 600 n_per_sqm
seismic load calc live load(rooftop plaza balcony)
Design- region
- Japan
- method
- 建築基準法施行令第85条 表(1)欄
- 2,900 n_per_sqm
floor structural calc live load(rooftop plaza balcony school department store)
Design- region
- Japan
- method
- 建築基準法施行令第85条 表(4)欄